NAV Series TCP/IP Standalone Network Access Controller
32
4.7.4 AlarmIN Setting
Select the “AlarmIN Setting menu item and press “#” to enter its interface. Because the
controller only has one alarm input circuit, the system will display the alarm type of the
currentalarm input.The default alarm typeof the alarminput port of the system isa fire
alarm. The user can scroll to the alarm type to be set and press the numerical key “5” to
select.Press“#”tosavethecurrentsettingandenterthene xtstep.
4.7.4.1 Fire Alarm Setting
If theset alarm typeis a fire alarm,the fireAlarm Settinginterface will be displayed. The
input mode (Normally On and Normally Off) of fire alarm is set in this interface. The
NormallyOnmodeindicatesthattheinputsignalisintheoffstateunderthenormalstate
(no input) and the on state of the input indicates the input of an alarm signal. On the
contrary,theNormallyOffmodeindicatesthattheinputsignalisintheonstateunderthe
normalstateandtheoffstateofthe inputindicatestheinputofanalarmsignal.
Scrollto the presetinput mode,press“5” to select. Afterfinishingthe setup,press“#” to
savethecurrentsettingandenterthedoorandfirealarmlinkagesetupinterface.Incaseof
afirealarm,the doormayhave twoactions: open andclose.Press“#”to togglebetween
openandclose.
Thesystemdisplaysthecurrentdooractionwhenafirealarmsounds.Press“*”toexit,and
thesettingisfinalizeduponexit.
Door Action on
Alarming:
Close
#to toggle
Door Action on
Alarming:
Open
#to toggle
Input mode*NO
NC
Alarm Port 1
Y
A
larmIN Type:
Others
*Fire
Cancel Next
A
larmIN Type:
* Other
Fire
Cancel Next
A
larmIN Setting
Alarm Action Setting