2.2.3.2ConnectingtotheAlarmOutput
Thecontrolleronlyprovidesonepathofalarmoutput,correspondingtotheNo.4,6and
8outputextensionwiresonthebackplateofthecontroller.TheNo.6extensionwireisa
commonterminal(COM),theNo.4extensionwireisanormallyclosedterminal(NC),and
theNo.8extensionwireisanormallyopenedterminal(NO).
Usercansetdifferenteventscorrespondingtotherelevantrelays.Theoutputhasthree
terminals: common terminal, normally opened terminal and normally closed terminal.
The wire connection should be determined according to the alarm. Before wire
connection, please read the instructions of the external alarm. The wire connection
methodisshownasbelow.
Figure 2-9
Figure 2-10
2.2.4 Connecting to the Computer through the Network
UsercancarryoutbasicsettingthroughthekeypadontheEFC301controllerorconnection
with the computer via TCP /IP. User can carry complicated system administration by
accessingtheembeddedsysteminthecontrollerthroughvariousbrowsers.
Figure 2-11
Exteral
Alarming
Device
C.terminal
N.C. terminal
COM
N.C.
4
6
N.O.
COM
N.O. terminal
C.terminal
Exteral
Alarming
Device
6
8
TCP/IP