Vista de pagina 20
13
1313
13
Please NOTE:
1. The maximum current outputted by the door lock relay on the fingerprint is less
than 5A. If the current for door lock exceeds the capacity, an external power relay
is needed.
2. V+ in the figures represents one lead of power from an external power source.
When using DC Voltage for the lock, put the positive lead here. When using AC
the leads are interchangeable.
Connection to Request-to-Exit
When fingerprint controller receives a valid signal (closed connection) from the request-to-exit
device, like a button, the controller will unlock the door for the specified open time. Connect
the request-to-exit device to terminal 12 and 13, shown as the below figure:
Fig. 9. Connecting REX to Controller
Connection to Door Sensor
Door sensor presents the door status, i.e. if it is open (open circuit) or closed (short circuit).
Connect the two wires from door sensor to terminal 14 and 15 of fingerprint controller, shown
as the below figure:
Fig. 10. Example for Connecting Door Sensor to Controller
Connection to Alarm Input
Fingerprint controller supports 4 general alarm inputs, for example, a motion sensor or a glass
sensor. Normally the 4 alarm inputs can represent 4 arm zones, but they can be freely defined
based on the actual application. When a valid alarm input (closed circuit) is detected, the
13
DoorButton GND
12
EXIT
Door sensor
15
Door Sensor
GND
14