EverFocus EBC890 Manual de usuario

Busca en linea o descarga Manual de usuario para Controladores De Puerta De Seguridad EverFocus EBC890. EverFocus EBC890 User manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 64
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
User Manual
F
F
l
l
e
e
x
x
S
S
e
e
r
r
i
i
e
e
s
s
F
F
i
i
n
n
g
g
e
e
r
r
p
p
r
r
i
i
n
n
t
t
S
S
i
i
n
n
g
g
l
l
e
e
D
D
o
o
o
o
r
r
C
C
o
o
n
n
t
t
r
r
o
o
l
l
l
l
e
e
r
r
E
E
B
B
C
C
8
8
9
9
0
0
Volume
1
EverAccess
Vista de pagina 0
1 2 3 4 5 6 ... 63 64

Indice de contenidos

Pagina 1 - User Manual

User Manual FFlleexx SSeerriieess FFiinnggeerrpprriinntt SSiinnggllee DDoooorr CCoonnttrroolllleerr EEBBCC889900 Volume 1 EverAccess

Pagina 2

2222 Powerful alarm function: easy connection to alarm panel, ability to arm/disarm, specific fire alarm input with corresponding door control  S

Pagina 3 - Safety Warning

3333Controller Layout Figure 1.1 shows the layout of the EBC890 Fingerprint Access Controller along with its main components and their functions.

Pagina 4 - Table of Contents

4444The keypad provides an easy interface to operate the controller. (4) Terminals All the peripherals to the fingerprint controller are connected to

Pagina 5

5555The definitions of the terminals are found in the following table: Table 1. Fingerprint Controller Terminal Definition No Terminal Name Functio

Pagina 6

6666Installation Overview This chapter introduces the basic concept on how to install an access control system. The experienced installer can jump to

Pagina 7 - Chapter 8

7777 Fig. 3. Installation Overall Steps 1. One reader, basic access control The most basic configuration involves one card reader and an electric

Pagina 8 - Specifications

8888Adding a request to exit device to scenario 1 allows the system to control when to allow people to exit through a door. Request to exit devices

Pagina 9 - Product Overview

9999 Fig. 5. Common Door Configuration for Fingerprint Controller As the Fig. 5 shows, the fingerprint controller will first work as a controller

Pagina 10 - Parts List

10101010 Hardware Installation In this chapter, after preparing for the installation, the user is ready to begin the install. This section will d

Pagina 11 - Controller Layout

11111111 latches are in position. Then push down the controller a little bit to lock the position (marked as 2 in step 2 figure).

Pagina 12 - Terminal Definition

E V E R F O C U S E L E C T R O N I C S C O R P O R A T I O N EBC890 Instruction Guide  2004~2008 EverFocus Electronics Corp 1801 High

Pagina 13

12121212 must be powered separately from the controller. The mounting instructions for strikes and mag locks vary depending on the manufacturer an

Pagina 14 - Installation Overview

13131313 Please NOTE: 1. The maximum current outputted by the door lock relay on the fingerprint is less than 5A. If the current for door lock e

Pagina 15

14141414 controller will energize the specified alarm output relay. Fingerprint controller support 2 alarm output relay and the 4 alarm inputs can

Pagina 16 - EverAccess

15151515 Connection to Fire Alarm Fingerprint controller provides a special fire alarm input. Users can define either fail-safe or fail-secure as

Pagina 17

16161616 Connecting Fingerprint Controller and Computer Connection to Computer via RS232 As other EverAccess Flex series controller, the fing

Pagina 18 - Hardware Installation

17171717 Fig. 17. Connection to Computer via RS232 Connection to Desktop Reader via RS485 To connect the fingerprint controller to the desktop r

Pagina 19 - Connection to Door Lock

18181818 Fig. 19. Connections of Multiple Controllers A brief overview of the installation: 1. Connect the EverAccess desktop reader to the com

Pagina 20

19191919 0CLRWXYZT U VPQRSM N OJ K LG H I3D E FA B C214 5 6987SYSSYS78 965412A B C D E F3G H I J K L M N OPQRS T U V WXYZCLR0ENTARMEverAccessEverA

Pagina 21 - Connection to Door Sensor

20202020 TCP/IP Based System It is also possible to network the controller via TCP/IP in order to remotely manage the controller ov

Pagina 22 - Connection to Alarm Output

21212121 Connecting Power Connecting the Power Supply Connect the positive end to the terminal 47 and the GND to terminal 48 as shown in Fig. 24.

Pagina 23 - Connection to Door Bell

Read This First Read this instruction guide before you install or operate your EverAccess product. Note: Use this product only for the purpose for whi

Pagina 24 - Controller and Computer

22222222 Before First Use The operations must be performed in preparation before the first use: 1. Set the date and time for the controller 2.

Pagina 25 - Main module

23232323 Fingerprint Capture Before getting into the configuration of the fingerprint controller, the correct way to capture a fingerprint sample

Pagina 26 - RS485 Bus Extension

24242424 When the machine is processing, please hold the finger for a couple of seconds until RED LED is off, which means process is comple

Pagina 27

25252525 Controller Functionality and Configuration This chapter introduces system functions and their corresponding operations. Most ba

Pagina 28 - TCP/IP Based System

26262626 Enter System Configuration After the system installation is complete, the top line of controller LCD will display the current date and ti

Pagina 29 - Connecting Power

27272727 IF you present your card or enter index number first, LCD shows: Once the fingerprint is verified with administration privilege, contro

Pagina 30 - Before First Use

28282828 Enter System Setting Menu The following window appears after entering the system menu: Press to enter System Setting menu. Use an

Pagina 31 - Fingerprint Capture

29292929 Set Time Under the System Setting Menu, press at to set the time. The LCD will display the following menu. Use the numerical keys to e

Pagina 32 - Maintenance

30303030 Enter a new system PIN. Enter it a second time to confirm. Press to set the new system PIN. Pressing at any time will exit the menu

Pagina 33 - Configuration

31313131 Press to switch between Chinese and English. Press to leave. Set Time Server Setting The EverAccess Flex controlle

Pagina 34 - Verify System PIN

Table of Contents Specifications ...1 Chapter 1 Product

Pagina 35 - System Setting

32323232 Erase All Events The controller will record all events that occur, beginning immediately upon powering on. These events can

Pagina 36 - Set Date

33333333 Press to enter the Card Setting menu. Use and to choose from different menu options. All menu options under the Card Setting menu a

Pagina 37 - Set System Password

34343434 If adding fingerprint fails, it will go back to Add user first page. Delete Users The user can directly delete an individual user with a

Pagina 38 - Set Language

35353535 Press again to delete all users Caution: this operation will permanently delete ALL users from the controller database. Set User Prope

Pagina 39 - System Info

36363636 The arm status of the current card, i.e., enabled or disabled, will be displayed as shown below. Press to toggle between two statuses.

Pagina 40 - User Setting

37373737 Change Card Number for a User Under the following menu, press to change users’ card number: Present the new card or manually enter n

Pagina 41 - Add User

38383838 Show User Properties This function can be used to show the serial number of a card when it is swiped on the fingerprint

Pagina 42 - Delete Users

39393939 Press to enter this setting. Press to toggle between the two modes. Press to exit. Door Access Mode Setting The

Pagina 43 - Set User Properties

40404040 Open Time Setting This sets the door unlock time when the card is swiped or open door button is pushed. The default time is 3 seconds. T

Pagina 44

41414141 Set Door Control at Fire Alarm The controller allows the user to choose one of two behaviors to occur when a fire alarm is triggered: fa

Pagina 45

Connection to Desktop Reader via RS485 ...17 RS485 Bus Based Networking System...

Pagina 46 - Door Setting

42424242 Fire alarm, zone alarm 1~4, unknown user, expired user, invalid user, user PIN fail, invalid time zone, system PIN fail, ARM PIN fail, do

Pagina 47 - Door Access Mode Setting

43434343 ARM PIN Fail User is required to enter PIN when pressing to arm or disarm the system. An ARM PIN Fail event will be generated when a wr

Pagina 48 - Set Door Hold Open Time

44444444 Invalid Time Each user belongs to an access group. Each group has its own allowed doors and time zones. That is, users in the group have

Pagina 49 - Alarm Setting

45454545 Press to go to alarm settings for arm zone 2, 3, 4. Use steps outlined in “Fire Alarm” submenu to change settings. Arm Zone Setting

Pagina 50 - SYS PIN Fail

46464646 Press numeric keys 1~4 to toggle the status of corresponding arm zone between Y/N. Press to confirm. Press to exit without effecting

Pagina 51 - Expired User

47474747 Note the time out duration of alarm output can be different for each individual alarm and they can be set from the flex software, not fro

Pagina 52 - Zone Alarm 1~4

48484848 NOTE: If wrong password is entered three times, the controller keypad will be automatically locked for 1 minute. During this period keyp

Pagina 53 - Arm Zone Setting

49494949 Press to reset the alarm. If system is currently armed user will be prompted to disarm the system first. Please refer to previous secti

Pagina 54 - Alarm Output Mode

50505050 Software Setup Please Note: This is a brief instruction on EverAccess Flex Series Software for more detailed instruction guide please ref

Pagina 55 - ARM / DISARM

51515151 Setup the User Accounts for the Software A User of Flex series access control software is a person who operates the software at any user

Pagina 56 - Reset the Alarm

Restore Factory Settng...32 User Setting ...

Pagina 57

52525252 Keypad Settings define whether the reader is a keypad reader. The System Reader can be used to acquire the card’s serial numbe

Pagina 58 - Software Setup

53535353 Enroll Fingerprints for Card Holders Fingerprints for card holders can be enrolled not only from the controller, but also from the softwa

Pagina 59

54545454 Notes

Pagina 61

Headquarter Office 12F, No.79 Sec.1 Shin-Tai Wu Road, Hsi-Chi, Taipei, Taiwan Tel: +886-2-26982334 Fax: +886-2-26982380 Beijing off

Pagina 62

Alarm Output Mode ...46 Address Setting...

Pagina 63

Specifications Items Parameter User capacity 1000 (each user can register 2 fingerprints) Event record capacity 40,000 Maximum controllers connect

Pagina 64

1 Product Overview EBC890 is EverAccess® Flex series fingerprint controller, an advanced product that incorporates state-of-the-art fingerpr