NAV IP Access controller
55
Panic Open alarms are designed to allow users who are forced to enter a building under duress to
silently trigger an alarm. When the door’s access schedule is configured as PIN needed, for example:
“CardorPIN”or“CardplusPIN”,cardholderscantypeintheirpanicPINtotriggerapanicopeneventin
thesystem.
Thepanic PIN is the cardholder’soriginalPINplus any twodigits.Forexample, Sam’s PINis12345678.
He can type in any two more digits following“12345678” as the panic PIN, such as “1234567800”.The
timesettingforpanicopeneventisshowninthe
belowfigure:
Press numeric keys to input the specified alarm time for the event. Pressto confirm and press
todiscardthechangejustmade.
5.6.4.21 Event Alarm Action Setting
Pressatthebelowscreentoconfigureeventalarmactionsetting.
The event alarm action defines which alarm output can be triggered by the event. As we explained
before, NAV Controller can take main modules, up to 4 door modules and 1 alarm module, total 18
alarmoutput.Userswill
beabletoconfiguretheeventtotriggeranyoneormultipleoutputsfromthose
18alarmoutputs.
Theeventalarmactionsettingincludesthreesubmenus,showninbelow.
The alarm output setting on these three screens are the similar. For example, the fire alarm event
actionsondoormodule
willlooklike:
Thetoplineindicatesthe eventtobe configured. The bottom line is the setting of alarm outputs on4
door modules. Y indicates there is alarm output (relay energized) and N indicates there is no alarm
output (relay not energized). R refers specifically to alarm output
on the door module, indicating that
alarmoutputwillbegeneratedonlyiftheeventoccursonthecorrespondingdoor.Theaboveexample
meansthealarmoutputrelayatdoor1willbeenergizedifdoorforcedopeneventhappensonanydoor,
thealarmoutputrelayatdoor2does
notrespondtoanydoorforcedopenevent,andsameasdoor4to
8. Door 3 indicates the alarm output relay on door 3 will be energized if and only if the door 3 got a
forcedopenevent.
Note “R” option for alarm output does not apply to
alarm module and main module, since they don’t
naturallycorrespondtoadoorcontrol.
Intheabovemenu,pressnumerickey1~8totogglethealarm outputactionsofthiseventonthedoor
module among Y, N, and R (only for door module). Press andto navigate to other alarm
actionsettings.
Door Forced Open
YNRNNNN
Event Alarm action
on Alarm Module
Event Alarm action
on Door Module
Event Alarm action
on Main Module
EventAlarm action
Setting
Panic Open
000Min 10Sec