5.6.4.17 Door Act Setting On Fire
The controller allows the user to choose one of two behaviors to occur when a fire alarm istriggered:
fail‐safeorfail‐secure.Doorfail‐safeatfirealarmmeansthedoorwillbekeptunlockedwhenthereisa
firealarminput.Doorfail‐secureatfirealarmmeans
thedoorwillbelockedwhenthefirealarmcomes
in.
Insubmenulistof“AlarmInputSetting”,pressandtonavigatetothebelowsubmenutoset
thedoorbehavioratfirealarm:
Presstoentertothesetting,LCDscreenshowsthecurrentsettingstatusofthedoor
actionwhen
firmalarmistriggered.
In the menu shown above, press numeric key 1~8 to toggle the door action between fail‐safe and fail‐
secure. (The numbers correspond to the number of door modules installed in the controller) “Y”
indicatesfail‐safe;“N”indicatesfail‐secure.
The default setting for door control at fire alarm is all the doors are fail‐safe, i.e. all the doors will be
unlockedduringafirealarm.
5.6.4.18 Arm Delay Time Setting
When an arm operation is executed, all active arm zones will enter ARM enabled status only after a
certaintimedelay, whichiscalledARMdelaytime.Whenacardwith ARMenabledisswipedtopassa
door, system will not generate an alarm within the arm delay period so that cardholder has time to
disarmthesystem.
The details to set ARM delay time is as following. And the alarm delay time can be set to different
durations. In submenu list of “Alarm Input Setting”, pressandto navigate to the below
submenutosetthearmdelaytime:
Press tosetARMdelaytimeatthefollowingwindow:
Arm Delay Time
Setting
Door act onfire:
NNNNNNNN