EverFocus Eptz3000 Manual de usuario Pagina 19

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 39
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 18
2-18
Notice: Please make sure the power is off before setting, and restart the
EPTZ3000/EPTZ3000I to enable a new value after changing.
2.3.4. RS-485 Bus Terminal Resistance
For central controlling, the terminal resistance should be set for the device that is the
furthest one away from the controller. The 8
th
bit on the SW2 is a switch to enable or
disable the terminal resistance. When it is switched ON, the BUS terminal resistance is
connected.
ON
12345678
SW2
Protocol
Baud Rate
Terminal
Resistance
ON
12345678
OFF ON
ON
12345678
Keyboard
DVR
RS-485
Control Unit
n ≦ 255
Ternimal
Resistance
ON
CAM-0 CAM-1 CAM-n
Note: When the dome is out of control, or does not work under control well, try to switch
the terminal resistance ON.
Notice: Please make sure the power is off before setting, and restart the
EPTZ3000/EPTZ3000I to enable a new value after changing.
Vista de pagina 18
1 2 ... 14 15 16 17 18 19 20 21 22 23 24 ... 38 39

Comentarios a estos manuales

Sin comentarios