5. RESOLUTION
The resolutions for NTSC are 720x480, 720x240 (default) and 360x240.
The resolutions for PAL are 720x288, 720x576 (default) and 360x288.
NOTE: Changing the resolution will determine the amount of IPS the DVR will support.
Model
Resolution (N/P)
IPS (N/P)
360 x 240 / 360 x 288 120/100
720 x 240 / 720 x 288 60/50
D1/F1
720 x 480 / 720 x 576 30/25
360 x 240 / 360 x 288 240/200
720 x 240 / 720 x 288 120/100
D2/F2
720 x 480 / 720 x 576 60/50
360 x 240 / 360 x 288 480/400
720 x 240 / 720 x 288 240/200
D3
720 x 480 / 720 x 576 120/100
6. RECORD MODE
REWRITE: Continuous recording. Disk will be overwritten if it is full.
STOP: Stop recording when disk is full.
7. AUTOWRITE WITHIN
You can set DVR to automatically overwrite after the selected number of days. If you do
not wish to use this function, simply select “0”.
8. PRE-ALARM RECORDING
Select “YES” to enable pre-alarm recording function. Select “NOto disable pre-alarm
recording function.
9. RELAY OUT
By selecting 1”, user can easily identify whether DVR is recording or not if relay output
is connected to a signaling device. Select NONE if you do not wish to identify
recording status.
Note: For EDVRD3 model, 1/2/3/4 relay output is selectable.