EverFocus Flex1.0 Manual de usuario Pagina 11

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 19
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 10
Required Cabling
Required CablingRequired Cabling
Required Cabling
10GBASE-CX4
Twinax CX4 (0.5 to 15m)
NOTE:
NOTE:NOTE:
NOTE:
For available cables; please see the "Options" section below of this QuickSpecs.
Maximum Distances
Multimode OM1
62.5/125 micron
Multimode OM2
50/125 micron
Multimode OM3
50/125 micron
Singlemode
9 micron
SR
2 - 26m/33m*
2 - 82m
2 - 300m
LR
2 -10km
LRM
0.5 - 220m 0.5 - 220m 0.5 - 220m
* 26m at 160MHz and 33m at 200MHz.
NOTE:
NOTE:NOTE:
NOTE:
For additional information on 10Gb cable specifications go to:
http://www.hewlett-packard.com/rnd/pdfs/10gig_cabling_
technical_brief.pdf
Stacking Configuration
Stacking ConfigurationStacking Configuration
Stacking Configuration
Stacking links are used to interconnect Virtual Connect Ethernet Modules when using more than one
enclosure or when using more than two Virtual Connect Ethernet Modules in a single enclosure.
All Virtual Connect Modules within the VC Domain must be interconnected. Any combination of 1Gb
and 10Gb cables can be used to interconnect the Virtual Connect Modules; however the following
provides recommended configurations (note that a built-in 10Gb link is provided between modules in
horizontally adjacent bays). Supported cable lengths on 10Gb uplinks are 3 to 15 meters and supported
10Gb stacking links (connecting between two HP Virtual Connect Ethernet Modules) are 0.5 to 7 meters.
Interconnecting the modules allows all Ethernet NICs on all server blades in the Virtual Connect domain
to have access to any Virtual Connect uplink port. By using these module-to-module links, a single pair
of uplinks can be used as the data center network connections for the entire Virtual Connect domain,
and allows any server blade to be connected to any Ethernet network.
NOTE:
NOTE:NOTE:
NOTE:
Supported module-to-module and multi-enclosure stacking configurations may be found in the
HP Virtual Connect for c-Class BladeSystem Setup and Installation Guide which can be downloaded at
the following address:
HP Virtual Connect for c-Class BladeSystem and Installation Guide
QuickSpecs
HP Virtual Connect Flex-10 10Gb Ethernet Module for
HP Virtual Connect Flex-10 10Gb Ethernet Module forHP Virtual Connect Flex-10 10Gb Ethernet Module for
HP Virtual Connect Flex-10 10Gb Ethernet Module for
c-Class BladeSystem
c-Class BladeSystemc-Class BladeSystem
c-Class BladeSystem
Supported Products
DA - 13127 North America — Version 12 — January 14, 2011
Page 11
Vista de pagina 10
1 2 ... 6 7 8 9 10 11 12 13 14 15 16 17 18 19

Comentarios a estos manuales

Sin comentarios