NAV IP Access controller
44
reader is set as a non‐keypad reader. Flex controller will display the door number according to the
number of installed door modules. In the following example, 4 door modules (8 readers) have been
installedonthecontroller.
Pressnumeric keystotoggle the keypadsettingofcorrespondingreader.Press
to confirm.Press
toexitwithouteffectinganychange.
5.8.4ReadertoDoorAllocation
NAVControllercanbeflexiblyconfigured.Readerscanbeallocatedtodifferentdoors,andcanbesetas
ENTERonlyorEXITonly.Bydefault,eachreaderisallocatedasENTERonlytothedoorwiththereader’s
number.Atthefollowingsubmenu:
PresstoenterReadertoDoorAllocationsetting.Systemwillshowtheallocationofthefirstreader
todoorasfollowing:
Pressanyofthe1‐8numerickeystoallocatethecurrentreadertocorrespondingdoors.(Thisdepends
ontheactualdoormodulesinstalledon the controller) Pressthe
samenumeric key totoggle between
ENTERonly(IN)andEXITonly(OUT).
Pressthe ortoselectthedifferentreaders.Press toexit.
5.8.5ReaderBacklightSetting
Atthefollowingsubmenu:
Pressto enter Reader Backlight Setting. As shown below, the system will show if the backlight
setting of all readers are turned on or off. Y indicates ON, N indicates OFF. The default setting of
backlightisOFF.NotethisfeatureonlyappliesthereaderreleasedafterQ3,2010.
Press
anyofthe1‐8numerickeystochangethebacklightsettingofeachreader.Presstoexit.
5.8.6SetReaderLEDorLCDformat
Atthefollowingsubmenu:
12345678
NNNNNNNN
Reader Backlight
Setting
Reader-1
Door-1-IN
Reader to Door
Allocation
12345678
NNNNNNNN
Comentarios a estos manuales