N.O. Trans.: When the alarm is triggered, buzzer starts to function no matter how
long the alarm duration is set until you set it back to N.O.
N.C. Trans.: When the alarm is triggered, buzzer starts to function no matter how
long the alarm duration is set until you set it back to N.C.
¾ LOG
YES: Select YES if you wish to record Alarm Events in the Log.
NO: Select NO if you do not wish to record Alarm Events in the Log.
¾ ACTIVE CAMERA: This field is to activate camera you want to have the alarm
enabled too. For example if you had an external motion detector on camera one
you would set this option to camera one. The Default from the factory is set to on.
To change this, simply use the Jog Dial on the DVR to make your selection.
Active camera setting, from camera 01~16. You can set the camera which
corresponds to the place where the alarm is located.
Note: The recording camera number in an event depends on the alarm number, and
the active camera images will not be recorded. Example: You assign camera 3 as the
active camera to alarm 1. When the alarm 1 is triggered, camera 3 will be displayed
and camera 1 will be recorded.
¾ PTZ PRESET: Select PTZ PRESET from “001” to “255”, so that when Alarm
occurs, speed dome will turn to this preset position for event recording. This function
improves surveillance quality of an alarm event. If you wish to disable this function,
please simply select “OFF”.
¾ DURATION: The amount of time an alarm event will record - from 1 sec to 99
seconds. The default value is 5 seconds.
¾ ALARM OUTPUT: This will transmit a signal to another device. The setting of
alarms are NONE = not activated, 1 = output signal 1 transmitted, 2 = output
signal 2 transmitted, 3 = output signal 3 transmitted and 4 = output signal 4
transmitted.
¾ ALARM EMAIL: Select “YES” for sending an email when alarm occurs. The
email address can be set in the NETWORK SETUP MENU.
¾ BUZZER: Audible alarm buzzer.
ENABLE: To enable an alarm buzzer.