- 83 -
Select CONFIGURATION to open the configuration menu:
Select
DOWNLOAD to load the current EPS 100 configuration.
The following values can be changed:
IP address: internal EPS 100 IP address
Netmask: subnet mask of the LAN EPS 100 is connected to
Gateway: gateway address of network / router
Control port: normal EPS 100 communication port, standard value is 23.
Additionally, port 99 is used for configuration up- and
download
MAC address: EPS 100 MAC address (display only)
Version: display of hard- and software version
Out-IP IP address: client PC address for receiving network alarm messages
Out-IP Port: TCP port for network alarm transmission
ATTENTION: Please make sure that PowerCon alarm receiver
monitoring this port is set to TCP receiving mode!
Input Alarm Trigger: if checkbox is activated, the assigned switch input is active
(reacts on switching).
Output initial state: Standard setting of the switch outputs. All checked outputs are
set to ON after configuration upload or power loss.
After entering changes, select
UPLOAD CONFIGURATION to transfer the
configuration to EPS-100.
Select SAVE to save this setting in the client PC database and to close the window.
For changing input or output descriptions, select INPUT or OUTPUT and EDIT: