14
* All product specications are based on existing products and are subject to change without notice. * Models vary in different countries. Please visit EverFocus regional websites for detailed ordering information
Features Specications
Dimensions
• Large storage capacity: Supports up to 3, 000 users and 30, 000
event log entries
• Flexible operating mode: The ngerprint unit may function
independently or may be connected with a computer; the software
controls communications in real time
• Feature-rich management functions: Capable of conducting access
administration based on time, date, location, and cardholder's access
privileges
• Powerful alarm features: Connectivity with the alarm server for
the ARM/DISARM of controlled areas; the triggering of a re alarm
will effect controls to the appropriate door areas, which provides
convenient connectivity
• Up to 13 door access types to provide customers with convenient
options to suit their needs
• Backlit LCD display (2x10 Chinese, 2x20 English/Russian) and backlit
keyboard operation area
• Equipped with Wiegand 26 output format
• When connected with external Wiegand 26 or RS232 card readers,
requirements for single-door two-way card access can be fullled
• The protective features of TVS safeguards the ngerprint unit against
damage resulting from transient high voltage
• Operating independently or in real-time communication with a PC.
The ngerprint unit can function by itself or work with the PC's access
control software in real time
EBC900R/M
Flex II RS232/485 Fingerprint Access Controller
Standalone Model
179.6mm/7.07”
137.5mm/5.41”
EBC900R
ID Fingerprint Access
Control Standalone Model
EBC900M
IC Fingerprint Access
Control Standalone Model
Frequency 125KHz 13.56MHz
Card Format ID card (EM) IC card
Max. Users 3, 000 (2 ngerprints may be registered for Each user)
Max. Log Entries 30, 000 entries
Max. Fingerprint Units
Connected via RS485
127 units, with unlimited expandability
Fingerprint Identication
Time
1:1:<1 sec
1:N:<2 sec (3, 000 users)
Error Rate 0.00001%
Automatic Finger
Detection
YES
Door Access Mode 13 types
Controllable Doors 1
External Card Reader 1
Output Format Wiegand 26 format
User Password 8 Characters
System Password 8 Characters
Alarm Management
Password
8 Characters
Alarm Inputs 5 Channels of controlled area alarm inputs
Alarm Outputs
3 Channels of alarm outputs (1 of which is tamper-
proof)
Communications
Interface
RS232 or RS485
Baud Rate 9600 bps
Programmable Time
Intervals
10 intervals per day with 1 minute minimum per interval
Programmable Dates
3 types available with up to 384 types of date
congurations
Groups 256
Expiration of Card YES
Automatic Daylight
Savings Time
YES
Keyboard 4x4, backlit
LCD Display Backlit, 2x10 Chinese, 2x20 English/Russian
Real Time Clock YES
Max. Door Relay Current
5A
Max. Alarm Relay Current
2A
Voltage DC12V±15%
Current 1A
Temperature -10°C~+50°C
Dimensions (L x W x H) 179.6 x 137.5 x 48mm/7.07" x 5.41" x 1.9"
RS232/485 Access Controller
Flex II Series Fingerprint Unit
RS232/485 Access Controller