10.2 Remote Control Protocol
A computer or a terminal can be used to control the unit by sending the packet as following.
Interface Specifications
45
=========================================================
Digital video recorder RS 485/232 Control Code Protocol
=========================================================
1-1. Sample control code packets
Example1 : A packet that send "REC" key to Digital Video Recorder (ID=5)
0x85 (length)
0x00 (Receiver ID high byte)
0x05 (Receiver ID low byte)
0x4B (OPcode = key )
0x08 (DATA1 = "Rec" keycode )
0x5D (checksum)
Example2 : A packet that send "PAUSE" key to Digital Video Recorder (ID=4999)
0x85 (length)
0x27 (Receiver ID high byte)
0x07 (Receiver ID low byte)
0x4B (OPcode = key )
0x0C (DATA1 = "Pause" keycode )
0x0A (checksum)
Example3 : A packet that send "PLAY" key to all Digital Video Recorder (broadcast)
0x85 (length)
0x7f (Receiver ID high byte)
0x7f (Receiver ID low byte)
0x4B (OPcode = key )
0x0B (DATA1 = "Play" keycode )
0x59 (checksum)