EZN850 User’s Manual Copyright © EverFocus Electronics Corp, Release: Dec. 2009 Rev.C
EZN850 10
EZN850 114.1 System Info System information and system log check of the setup menu can be performed on this page. The “System Info” page has 2 tab
EZN850 124.1.2 Log System Log: Date/Time: displaying date and time of the log. Log message: all information and event message, including logi
EZN850 134.2 User Config Live view configuration is to be set by user. Each login user can make his/her own settings for the following items: Te
EZN850 14 Time Format: 24 Hours or 12 Hours. Press Apply to apply the setting changes or Reset to reset without saving the change. Recording/Sna
EZN850 15Press Apply to apply the setting changes or Reset to reset without saving the change. 4.3 Network The network settings and the settings
EZN850 16IP Setting IP Type DHCP: Configure the DHCP server not to assign the same IP addresses used for the other network cameras and PCs whose
EZN850 17Password Enter Password of the account (used only for PPPoE). Press Apply to apply the setting changes or Reset to reset without saving
EZN850 18server. We offer 4 DDNS server providers as follow: ○ www.everfocusddns.com ○ www.sitelutions.com ○ www.dyndns.com ○ www.no-ip.com E
EZN850 19Bandwidth Setting Max. Bandwidth: Specify, Unlimited / 64 K/ 128 K/ 256 K / 512 K / 1M / 2M / 4M / 8M bps. the maximum bandwidth that the
EZN850 2Product Name: EZN850 EverFocus IP Network Cameras Model Number(s): EZN850 FCC Notice "Declaration of Conformity Information" Th
EZN850 20send e-mails. SMTP Port: Enter the port number for SMTP. Default is 25. Authentication: Check the box, if the SMTP server requires Auth
EZN850 214.3.5 Network Alarm (reserved for PowerCon) Set Network Alarm This function is reserved for PowerCon software, for the detail setting p
EZN850 224.4.1 Multi Streaming Stream Setting The system can output 4 video streams simultaneously. For each of them, user can set compression f
EZN850 23Press Apply to apply the setting changes or Reset to reset without saving the change. Video Recording Setting User can set video recordi
EZN850 24To adjust the viewing range, press “++” , “+” sign of Zoom to zoom out, and “-“ , “--“ sign of Zoom to zoom in. Press “++”, “+“, “-“ or
EZN850 25 2. Please click SET key for saving setting and return to the previous menu. 4.4.2.2 SHUTTER 1. When the SETUP menu is disp
EZN850 26Ö ESC: (Reserved). Ö Manual: (Reserved). 3. Click the SET key when you finish all the settings. 4.4.2.3 WHITE B
EZN850 27adjust the white balance again. Ö MANUAL: The manual adjustment mode enables a more precise adjustment. Please select ATW or AWC first.
EZN850 28Ö HIGH: The gain increases from 0dB up to 42dB. Ö MIDDLE: The gain increases from 0dB up to 30dB. Ö LOW: The gain increases from 0dB u
EZN850 29 Ö OFF: No reduction in noise level. Ö LOW: Little reduction in noise level with nearly no ghost image. Default value is LOW. Ö
EZN850 3 About this document All the safety and operating instructions should be read and followed before the unit is operated. This manual should
EZN850 303. Click the SET key when you finish all the settings. 4.4.2.8 SPECIAL 1. Please direct the arrow to point to “SPECIAL” on
EZN850 313) Click the SET key. 4) Maximum 15 letters can be used for the ID. ¾ Clicking UP (c), DOWN (d), LEFT (e) or RIGHT (f) key to select the
EZN850 324.4.2.8.2 COLOR ADJ Adjust the Color Gain from 0 ~ 15 4.4.2.8.3 SYNC There are two SYNCHRONIZATION modes: INTERNAL and EXTERNAL
EZN850 33 z Please select the area you would like to detect from the 4 areas in AREA SEL mode. z Please select ON mode for the chosen ar
EZN850 342. Increase DOWN scale value by 20. AREA1 position after change is: TOP: 10, DOWN: 45, LEFT: 20 and RIGHT: 40. 3. Increase TOP s
EZN850 35 4.4.2.8.5 PRIVACY This mode covers the areas you do not want to see on the screen. 1) Please direct the arrow to point to “PRIVACY” b
EZN850 361. The original position of AREA1 was TOP: 10, DOWN: 25, LEFT: 20 and RIGHT: 40. 2. Increase DOWN scale value by 20. AREA1 posi
EZN850 375. Increase LEFT scale value by 20. AREA1 position after change is: TOP: 30, DOWN: 45, LEFT: 40 and RIGHT: 60. z In order to save
EZN850 384.4.2.8.8 RESET Click SET key on “RESET” for 3 seconds until it restarts. It will go to factory default value. 4.4.2.8.9 RETURN C
EZN850 394.5 USER User Information Maximum 10 users can be set for using the IP camera. The user information displays the authorized users and a
EZN850 4this appliance is 24VAC or 100VAC~240VAC. Use only the recommended power supplies. Power supplies must comply with the requirement of t
EZN850 404.6 EVENT An event in the camera is when an Event Type is activated and causes certain actions to be performed. The event type is the set
EZN850 414.6.1 Event The settings relating to event occurrences such as settings for the event occurrence, motion, alarm and time mask can be conf
EZN850 42To change the priority of events, click on the event and it will be highlighted. Press or button to move between events. The event th
EZN850 435. Check “Enable Pre-alarm Buffer” and “Enable Post-alarm Buffer”. For pre-and post alarm buffer setting, please refer to “4.6.3 Alarm”.
EZN850 442. Press to have the entire screen selected for motion detection. Press to clear all selections. Press and click on the polygon,
EZN850 45Alarm Output Setting Contact Type: Normal Close, Normal Open Duration Time: Select duration time of alarm output from 5 sec, 10 sec, 20
EZN850 464.6.4 Time Mask Time Mask Setting Time mask setting allows you to schedule event actions. Select Always for event action to be taken
EZN850 474.7 SYSTEM Date/Time, Daylight Saving, SD card and Maintenance settings can be performed on this page. The "System" page has 4
EZN850 48 Time: Click on Hour, Minute, Seconds, am/pm; then use up arrow to increase value and down arrow to decrease value. Press Apply to apply
EZN850 494.7.2 Daylight Saving Set Daylight Saving Check Enable Daylight Saving checkbox to enable daylight saving. Set the st
EZN850 5TABLE OF CONTENTS 1. INTRODUCTION...6 2.
EZN850 50“End” time when daylight saving ends. Press Apply to apply the setting changes or Reset to reset without saving the change. 4.7.3 SD
EZN850 51-Normal: Follow the event actions settings you have made in “Event” menu to record event video to SD card. -Overwrite: Select ON for over
EZN850 52 3. Enter administrator user name and password. (user1, 11111111) 4. Then you can download video or image file from SD card. The file
EZN850 534.7.4 Serial Communication RS485 Setting Camera ID: This entry is used to assign camera own ID code. Baud Rate: This field is to set t
EZN850 54 Press Apply to apply the setting changes or Reset to reset without saving the change. 4.7.5 Maintenance Maintenance Server Reboot: T
EZN850 55Save/Load Configuration Server To take a backup of all of the configurations, press Save to save all configurations to a config. file. I
EZN850 565. SPECIFICATIONS CAMERA Pickup Device 1/3"Sony super HAD CCD Pixel Effective NTSC: 768 (H) x 494 (V); PAL: 752 (H) x 582 (V) Sen
EZN850 57Weight 2.5kg ; 5.5lbs (3.0kg ; 6.6LBS with bracket) ENVIRONMENTAL Operating Temp. -40°C ~ 50°C ; -40°F ~ 122°F Humidity 20~80% Heate
EZN850 58 EverFocus Electronics Corp. Head Office: 12F, No.79 Sec. 1 Shin-Tai Wu Road, Hsi-Chih, Taipei, Taiwan TEL: +886-2-26982334 FAX: +886-2
EZN850 61. INTRODUCTION EZN850 network camera utilizes H.264, MPEG-4 and MJPEG compression for multiple streaming outputs. Engineered with the adv
3. ACCESSING THE CAMERA MENU Step 1. Start an Internet Explorer browser. Step 2. Enter the IP address or host name of the camera in the Location/Addre
EZN850 8are 7 sections: [System Info], [User Config], [Network], [Video], [User], [Event] and [System]. Please refer to “4. Setting” for further i
EZN850 9○8 Snapshot The Snapshot button saves a snapshot of the video image currently being displayed. The location where the snapshot data is s