11
10
(25)
(26)
9
Fig. 4.4 Example for connecting door sensor to controller
NOTE: Among these four terminals, terminal 9 and 25 are GND, shared by
the door sensor and request-to exit
Connection to Request-to-exit
The door module also provides an interface to the request-to-exit button or sensor.
Door 1 and door 2 are connected to terminal 8, 9 and 24, 25 respectively.
(24)
(25)
8
9
Fig. 4.5 Connecting REX to controller
NOTE: Among these four terminals, terminal 9 and 25 are GND, shared by
the door sensor and request-to exit
Door sensor
Door
module
Door
module
EXIT