EverFocus EDSR100M Manual de instrucciones Pagina 40

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 62
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 39
MENU
(1) RS232/RS485: Choose RS232 or RS485 for activated.
(2) RS232/RS485 ID: This entry is used to assign each device with its own ID code, when more than on unit is
used in one system through RS232/RS485.
There are two ID code for the Digital video recorder : 001 or 002
(3) BAUD RATE: There are 6 different speeds that can be used to transmit instruction or
information through the RS232/RS485 port on the device, 1200 baud,2400 baud,4800 baud,9600 baud,
19200 baud,and 3840 baud. The default setting from the factory is 9600 baud.
(4) PARITY: Select parity lever: NONE/ODE/EVEN
(5) DATA BIT: Select data bit : 8 or 7
(6) STOP BIT:Select stop bit: 1 or 2
27
RS232/RS485 SETTING MENU
6.8 RS232/RS485 SETTING MENU
RS232/RS485
RS232/RS485 ID
BAUD RATE
PARITY
DATA BIT
STOP BIT
In the RS232/RS485 SETTING MENU, we define
: RS232
: 01
: 9600
: NONE
: 8
: 2
Left/Right Button: Press or to move the cursor to the left or right
Up/Down Button: Press or to change the value.
Vista de pagina 39
1 2 ... 35 36 37 38 39 40 41 42 43 44 45 ... 61 62

Comentarios a estos manuales

Sin comentarios