5) Make sure the “Baud” rate is 9600, the “data” is 8, the “stop” bit is 1, the
“Parity” is “n”, the “Flowctrl” is “none”. For the “Type”, choose the type
of connection you wish to use.
a. For RS232 connection, choose “RS232”
b. For RS485 connection, choose “RS485_HALF”
6) Click “Submit” button.
7) Click on “Save Configurations” on the left side.
8) Click “Save” button to save configurations.
9) Click on “Reboot” on the left side.
10) Click the “Reboot” button.
This will close the Web page reboot the server with new configurations.