EverFocus ECOR960 16F2 Manual de usuario Pagina 26

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 149
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 25
ECOR960 4F2 / 8F2 / 16F2
17
2.2.2 Alarm I / O
The DVR provides 4 alarm inputs and 1 alarm outputs. Please refer to the table below for PIN
assignment.
COM NC G G 4 3 G G 2 1
Alarm Out Alarm In
Figure 2-13
Alarm Input
No.
Description
1-4
ALM_IN1 ALM_IN4
G GND
Alarm Input Contacts
This DVR provides one alarm input per camera. All inputs are programmable N.O. (Normal
Open) or N.C. (Normal Closed). All settings are programmed in the ALARM / Event menu.
ALMIN
GND
ALMIN
GND
Alarm Input with N.O. contact in idle state Alarm Input with N.C. contact in idle state
Alarm Output Contacts
The relay output provides Normally Closed dry contacts.
Vista de pagina 25
1 2 ... 21 22 23 24 25 26 27 28 29 30 31 ... 148 149

Comentarios a estos manuales