EverFocus EDR1620 Manual de usuario Pagina 32

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 77
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 31
3.4 ALARM SETUP MENU
In the ALARM SETUP MENU, we define :
(1) ALARM:
ENABLE: Enable alarm detection.
DISABLE: Disable alarm detection.
(2) ALARM TYPE:
N. O. : Normal Open alarm.
N.C. TRANS. : When the alarm is triggered, buzzer starts to function no matter how long is the
alarm duration set until you set it back to N.C.
N.O. TRANS. : When the alarm is triggered, buzzer starts to function no matter how long is the
alarm duration set until you set it back to N.O.
N. C. : Normal Close alarm.
(3) ACTIVE CAMERA:
Active camera setting, from camera 01~16. You can set the camera which corresponds to the place
where the alarm is located.
Note: The recording camera number in an event depends on the alarm number, and the focus camera
images will not be recorded. For example: You assign camera 3 as the focus camera to alarm 1.
When the alarm 1 is triggered, camera 3 will be displayed and camera 1 will be recorded.
31
Vista de pagina 31
1 2 ... 27 28 29 30 31 32 33 34 35 36 37 ... 76 77

Comentarios a estos manuales

Sin comentarios