Cameras with IR LED
12
ED 335 - 8,5 mm (1/3") indoor day / night 3-axis dome camera with IR LED, high resolution,
automatic IR cut filter
Features
high resolution technology (520 TV lines)
IR range up to 20 m
integrated DC varifocal lens (f=2,8 ~ 10 mm)
3-axis rotation for flexible viewing angle
mounting options for surface or flush mounting
day/night switching with automatic IR cut filter
optional wall bracket
Technical data
Sensor 8,5 mm (1/3") SONY Super HAD CCD
Picture element 752 x 582 (PAL)
Horizontal resolution 520 TV lines
Sensitivity 0,4 lux / F = 1.2 (AGC on), 0 lux (IR LED on)
Video output 1 Vp-p composite PAL, BNC, test video output 1,0 Vp-p, 75 Ohm
Day/night switching automatically swiveling IR cut lter
IR LED wavelength 850 nm
IR LED lifetime up to 20.000 h
IR range up to 20 m, depending on reections in scenery
S/N ratio over 48 dB (AGC o)
Gamma correction > 0,45
Synchronisation internal
Back light compensation yes
Auto white balance yes
AGC yes
Electronic shutter 1:50 ~ 1:100.000
Lens DC varifocal lens, f= 2,8 ~ 10 mm
Mounting surface or ush (in-ceiling) mounting
Power source 12 V DC / 24 V AC
Power consumption 12 V DC: 6 W max., 24 V AC: 6,5 W max.
Ambient temperature 0°C ~ +40°C
Dimensions (diameter x H) 140 x 128 mm (surface mounting) / 140 x 68 mm (ush mounting)
Weight 660 g
Ordering information
ED 335 / P
8,5 mm (1/3") indoor day/night 3-axis dome camera with IR LED, high resolution, automatic IR cut lter,
12 V DC / 24 V AC
ED WMA 02 Wall mount bracket
AP12A122E0 Power supply, 230 V AC / 12 V DC, 600 mA
ED WMA 02 - wall mount
bracket
Material: aluminium
Dimensions (WxHxD): 150 x 110 x 170 mm
Weight: 600 g
Max. load: 4 kg
Application: with ED 335
* The IR illumination range depends on the location, particularly with regard to the reflection of the installation's
surroundings. Locating the device near to highly absorbent surfaces can result in a significantly reduced range.
Vista de pagina 11
1 2 ... 7 8 9 10 11 12 13 14 15 16 17 ... 59 60

Comentarios a estos manuales

Sin comentarios